The electric heating distilled water machine uses purified water as raw water, and electric energy as heat source. The distilled water produced completely conforms to the quality indicators of USP, EP, JP and ChP on "water for injection".
The electric heating pipe used for the steam generator of this machine complies with the provisions of JB/T2379, and the shell material of the electric heating pipe is made of austenitic stainless steel 00Cr17Nr14Mo2. This machine is suitable for production places where factory steam cannot be provided. It is an ideal distilled water professional production equipment for pharmaceutical factories, hospitals, biochemical research departments, etc.
Specification | Output of Distilled Water(L/h) | Purified Water Consumption (L/h) | Electricity Consumption (KW) | Overall Dimension L×W×H(mm) |
DLD50-3 | >50 | 60 | 24 | 1100x700x2000 |
DLD100-4 | >100 | 120 | 36 | 1300x900x2200 |
DLD200-4 | >200 | 240 | 72 | 1500x900x2300 |
DLD300-4 | >300 | 360 | 96 | 1700x1000x2500 |
DLD500-5 | >500 | 600 | 120 | 2200x1200x2700 |
DLD1000-5 | >1000 | 1200 | 240 | 2600x1300x2900 |
Industrial steam is the most cost-effective heating source for multi effect distilled water machine.
In places without industrial steam, electric heating can be selected if conditions permit. Electric energy is converted into heat energy as an alternative energy for industrial steam.
Unique three-stage separation mode to fully ensure the effluent quality.
Electric heating is adopted to convert electric energy into heat energy.
Pure steam output module (optional).
PLC+HMI full-automatic control mode.
Fully comply with GMP, USP and cGMP requirements.
Phone:
E-mail:
Address:
Room 1904, Building 10, No. 218, Jiqingmen Street, Jianye District, Nanjing, Jiangsu, China